BACKGROUND Procedures in medical papers should be described in sufficient detail to allow other researchers to reproduce the results. The apparatus including anesthesia machine should be given, too. Anesthesia machine has dramatically improved as bioengineering has developed. There are several ventilator settings in modern anesthesia machines. However, it seems that only a few ventilator settings are described even though modern ventilators are used in research. The purpose of this study is to investigate that how many ventilator parameters were described in the papers of the Korean Journal of Anesthesiology from 2001 to 2006. METHODS: All of papers with human general anesthesia were reviewed except case reports, and papers regarding only induction or intubation procedures. Recruited articles were grouped into papers with strongly related to respiratory parameters (STP), and into ones with slightly related to them based on the research topics. The description of following categories was counted in each paper; the type of anesthesia machine, tidal volume, respiratory rate, inspiratory:expiratory ratio, mode of ventilation, pressure set in pressure targeted ventilation, positive end expiratory pressure, inspiratory pause, and inspiratory rising rate. RESULTS: The description rate of each parameters in STP were 36% in the type of anesthesia machine, 66% in tidal volume, 54% in respiratory rate, and 24% in inspiratory:expiratory ratio.
The other settings were seldomly mentioned. CONCLUSIONS: Description on the ventilator parameters was sometimes missed. We should describe adequate ventilator settings to reproduce the results because the modern anesthesia machine has additional ventilator options.