| Home | E-Submission | Sitemap | Contact us |  
Korean J Crit Care Med > Volume 22(1); 2007 > Article
Korean Journal of Critical Care Medicine 2007;22(1): 7-14.
마취기를 이용한 인공호흡 관련 연구에서 각종 인공호흡 지표의 서술에 대한 분석
심지연ㆍ박희연*ㆍ안원식*
울산대학교 의과대학 마취통증의학교실, *서울대학교 의과대학 마취과학교실
Analysis of the Description of Ventilator Parameters in Recent Papers Relating Artificial Ventilation Using Anesthesia Machine
Jiyeon Sim, Hee Yeon Park, Wonsik Ahn
1Seoul National University College of Medicine, Seoul, Korea.
2Department of Anesthesiology and Pain Medicine, College of Medicine, University of Ulsan, Korea.
ABSTRACT
BACKGROUND: Procedures in medical papers should be described in sufficient detail to allow other researchers to reproduce the results. The apparatus including anesthesia machine should be given, too. Anesthesia machine has dramatically improved as bioengineering has developed. There are several ventilator settings in modern anesthesia machines. However, it seems that only a few ventilator settings are described even though modern ventilators are used in research. The purpose of this study is to investigate that how many ventilator parameters were described in the papers of the Korean Journal of Anesthesiology from 2001 to 2006. METHODS: All of papers with human general anesthesia were reviewed except case reports, and papers regarding only induction or intubation procedures. Recruited articles were grouped into papers with strongly related to respiratory parameters (STP), and into ones with slightly related to them based on the research topics. The description of following categories was counted in each paper; the type of anesthesia machine, tidal volume, respiratory rate, inspiratory:expiratory ratio, mode of ventilation, pressure set in pressure targeted ventilation, positive end expiratory pressure, inspiratory pause, and inspiratory rising rate. RESULTS: The description rate of each parameters in STP were 36% in the type of anesthesia machine, 66% in tidal volume, 54% in respiratory rate, and 24% in inspiratory:expiratory ratio. The other settings were seldomly mentioned. CONCLUSIONS: Description on the ventilator parameters was sometimes missed. We should describe adequate ventilator settings to reproduce the results because the modern anesthesia machine has additional ventilator options.
Key Words: Artificial respiration; Description of methods; Inspiratory:expiratory ratio; Mechanical ventilators; Positive pressure respiration; Ventilator parameters
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
CrossRef TDM  CrossRef TDM
  E-Mail
Share:      
METRICS
485
View
26
Download
Related article
Editorial Office
#805-806, Yongseong Biztel, 109 Hangang-daero, Yongsan-gu, Seoul 04376, Korea
TEL: +82-2-2077-1533   FAX: +82-2-2077-1535   E-mail: acc@accjournal.org
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Critical Care Medicine. All rights reserved.                 developed in m2community
Close layer
prev next