| Home | E-Submission | Sitemap | Contact us |  
Korean J Crit Care Med > Volume 12(1); 1997 > Article
Korean Journal of Critical Care Medicine 1997;12(1): 49-56.
아산화질소를 이용한 흡입산소농도 변화시 혈액채취시기의 결정
오종인, 오수원, 구길희
중앙대학교부속 용산병원 마취과
The Adequate Timing of Arterial Blood Sampling during the Changes of Inspired Oxygen Fraction by Nitrous Oxide
Jong In Oh, Soo Won Oh, Gill Hoi Koo
Department of Anesthesiology, College of Medicine, Chung-Ang University, Seoul, Korea.
ABSTRACT
BACKGOUND: Arterial blood gas analysis is essential on diagnosis and treatment of hypoxia and acid-base imbalance. It is important to decide the timing of arterial blood sampling as well as sampling method, sample transport, and analysis of the results. So we investigated to the adequate timing of sampling when inspired oxygen fraction is changed from 0.5 to 1.0. METHODS: 20 patients were anesthetized with enflurane-N2O-O2 (FiO2=0.5), and paralyzed with pancuronium 0.07~0.08 mg/kg. Ventilation was controlled with Ohmeda 7000 ventilator (BOC Health Care Inc., Madison, USA), using a constant tidal volume of 10 ml/kg and respiration rate of 12/min. After 1 hour of anesthesia, the nitrous oxide inhalation was stopped and 100% oxygen was inhaled, and then arterial blood gas values were measured at 2 min intervals for 20 min, 5 min intervals for next 30 min, and 10 min later. Blood samlpes were drawn from the radial artery and measured immediately on a blood gas analyzer (Civa-Corning 288 Blood Gas System, Civa-Corning Diagnostic Corp., Medifield, USA). Determining the optimal time of sampling was performed with the rate of variation of PaO2 according to time progression, then the point at which the slope decreased abruptly was regarded as statistically significant timing. RESULTS: After 12 minute, arterial oxygen partial pressure was not any more changed significantly. There were no change of pH, arterial carbon dioxide partial pressure, oxygen saturation, base excess, and bicarbonate. CONCLUSION: The timing of arterial blood gas sampling in change with inspired oxygen fraction from 0.5 to 1.0 is about 12 minute later.
Key Words: Monitoring; arterial blood gas; oxygen; timing
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
CrossRef TDM  CrossRef TDM
Share:      
METRICS
1,092
View
9
Download
Related article
Editorial Office
#805-806, Yongseong Biztel, 109 Hangang-daero, Yongsan-gu, Seoul 04376, Korea
TEL: +82-2-2077-1533   FAX: +82-2-2077-1535   E-mail: acc@accjournal.org
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Critical Care Medicine.                 Developed in M2PI
Close layer
prev next