| Home | E-Submission | Sitemap | Contact us |  
Korean J Crit Care Med > Volume 20(1); 2005 > Article
Korean Journal of Critical Care Medicine 2005;20(1): 92-96.
One-lung Ventilation using Wire-guided Endobronchial Blocker and Single Lumen Endotracheal Tube: A Case Report
Hee Zoo Kim, Seung Hwan Oh, Chung Guk Park, Eun Hye Koo, Hye Ran Oh, Mi Kyoung Lee, Sang Ho Lim
Department of Anesthesiology and Pain Medicine, College of Medicine, Korea University, Seoul, Korea. andigi@korea.ac.kr
ABSTRACT
We had done one-lung ventilation using 9 Fr wire-guided endobronchial blocker and outer diameter 41-mm flexible fiberoptic bronchoscope in ruptured esophageal patient who expected difficult tracheal intubation and in esophageal cancer patient who was in need of mechanical ventilation during and after the operation.
Key Words: Flexible fiberoptic bronchoscope; Mechanical ventilation; One-lung ventilation; Wire- guided endobronchial blocker
Editorial Office
#805-806, Yongseong Biztel, 109 Hangang-daero, Yongsan-gu, Seoul 04376, Korea
TEL: +82-2-2077-1533   FAX: +82-2-2077-1535   E-mail: acc@accjournal.org
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Critical Care Medicine.                 Developed in M2PI
Close layer
prev next