Case Report A Sheared Catheter Fragment in the Wrist after Arterial Cannulation Attempt: A Case Report
Sue Young Lee, Hyo Seok Na, Mi Hyun Kim, Chong Soo Kim, Young Tae Jeon, Jung Won Hwang, Sang Hwan Do

DOI: https://doi.org/10.4266/kjccm.2010.25.2.118
1Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea. shdo@snu.ac.kr
2Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Korea.
3Department of Anesthesiology and Pain Medicine, Seoul National University Boramae Medical Center, Seoul, Korea.
  • 2,439 Views
  • 29 Download
  • 3 Crossref
  • 0 Scopus

Citations

Citations to this article as recorded by  Crossref logo
  • Fracture of an Intravenous Cannula in the Hand: A Case Report
    Seungho Woo, Sangun Nah, Giwoon Kim, Sangsoo Han
    Journal of Emergency Nursing.2023; 49(2): 156.     CrossRef
  • Iatrogenic catheter sheath shearing during radial artery cannulation
    Il-Seok Kim, Ho Kyun Shin, Dae Yu Kim
    Korean Journal of Anesthesiology.2013; 65(6 Suppl): S12.     CrossRef
  • A retained catheter fragment in radial artery caused by accidental catheter transection during arterial catheter removal
    Seung-Ki Moon, Jae-Chul Gong, Jun-Hyun Kim, Kyu Chang Lee, Hye Young Kim, Eun Kyung Choi, Myeong Jong Lee
    Journal of Anesthesia.2012; 26(4): 625.     CrossRef